Product & Structure
The MMO Plate Anode with Copper Conductive Rod is an assembled plate anode made of multiple titanium plates stacked together, with insulating spacers placed between the plates to keep a uniform plate gap and prevent short-circuiting.
II. Material & Dimension
The substrate is Grade 1 or Grade 2 commercially pure titanium under ASTM B265. Plate thickness is customizable within 1.0 to 3.0 mm, plate length and width are machined according to customer drawings, and the number of stacked plates can be determined by the equipment structure.
III. Coating System
The coating is mixed metal oxide, selected according to the working condition: RuO₂-IrO₂ for chlorine evolution and IrO₂-Ta₂O₅ for oxygen evolution. Coating loading ranges from 10 to 30 g/m² and can be increased for specific duty, with coating thickness controlled at 8 to 20 μm.
IV. Conductive, Fastening & Insulation Structure
The conductive part uses a T2 pure copper threaded rod, with a titanium sleeve welded on the outside as a transition layer and epoxy sealed so that the copper rod does not contact the electrolyte. The terminal is a threaded copper connection available in M8, M10 or M12, customizable on request. Fasteners are titanium alloy bolts with nuts and insulating gaskets; PP or PTFE spacers are used between plates and PP or PTFE sleeves on the bolt positions, preventing galvanic corrosion between dissimilar metals.
V. Electrical & Operating Parameters
Recommended current density is 200 to 3000 A/m² for oxygen evolution and 2000 to 8000 A/m² for chlorine evolution. Maximum working temperature is ≤80 ℃. Design service life is customizable, typically 2 to 5 years under rated conditions. Working media include brine, sodium chloride solution, sodium hypochlorite, acid wastewater and plating bath.
VI. Inspection & Quality
Factory inspection covers XRF coating composition analysis, ICP loading measurement, adhesion test and electrochemical polarization test, confirming that coating ratio, precious metal loading and bonding strength meet the technical requirements.
VII. Application
The product is mainly used in sodium hypochlorite generators, electroplating, electrolytic wastewater treatment, metal electrowinning and seawater electrolysis, as well as cathodic protection systems.